FDA's blood-level line is a cue to test, not a danger line
Under 0.5 ng/mL in the blood, with no other warning sign, a cancer study can be skipped. Above it, FDA asks for one; crossing the line is not a finding of harm.
What the references say
FDA's 0.5 ng/mL line marks where testing starts, not where harm does
FDA took it from a rule for untested chemicals: below 0.5 ng/mL in the blood, the cancer risk of an unknown compound after one dose would stay under 1 in 100,000, so with no other warning sign a cancer study could be skipped. A filter above it is not judged harmful; it needs that study.
The caveat · Set for cancer, not hormones
The line concerns cancer testing, and for oxybenzone FDA also names possible hormone activity as a reason the absorption data matter. The trial registry holds no trial testing cancer or hormone outcomes of any chemical filter.